Use of cutting-edge biomedical devices for intravenous cannulation in the health care of a patient: literature review
DOI:
https://doi.org/10.14528/snr.2017.51.1.141Keywords:
biomedical devices, intravenous cannula, nursing, difficult venous accessAbstract
Introduction: Biomedical devices are tools used for locating invisible and impalpable peripheral veins. The purpose of this article is to give a systematic review and analysis of existing studies on the available biomedical devices used for locating peripheral veins and on their effectiveness in clinical practice. Methods: Databases CINAHL, Medline and ScienceDirect were used for the literature review and analysis. The search was performed with the following key words in English: devices, visualization, technology, cannulation, vein, nursing care, with Boolean operators 'AND' and 'OR'. The analysis included randomized and experimental clinical studies published in the English language in the period from 2000 to August 2016. From a total of 1,020 retrieved studies, 17 were included in the detailed analysis. Results: The results of the analysis have shown that the success rate of the first attempt of intravenous cannulation using biomedical devices in more than half of the studies was not significantly higher than when the process was performed using the conventional method. The success of the first attempt of intravenous cannulation mostly depends on the experience and skills of nurses. Biomedical devices are more helpful for novice nurses who do not perform cannulation on a daily basis, for beginners and nursing students. Discussion and conclusions: Based on research, we cannot affirm that biomedical devices significantly contribute to easier peripheral venous cannulation. Further research is required to validate the advantages of such an approach. However, this is limited due to the affordability issues of such biomedical devices.
Downloads
Metrics
References
Alekseyev, S., Byrne M., Carpenter A., Franker C., Kidd C. & Hulton L., 2012. Prolonging the life of a patient's IV: an integrative review of intravenous securement devices. MEDSURG Nursing, 21(5), pp. 285–292. PMid:23243786
Arbique, D., Bordelon, M., Dragoo, R. & Huckaby, S., 2014. Ultrasound-guided access for peripheral intravenous therapy. MEDSURG Nursing, 23(3), pp. 1–15.
Aulagnier, J., Hoc, C., Mathieu, E., Dreyfus, J.F., Fischler, M. & Le Guen, M., 2014. Efficacy of Accuvein to facilitate peripheral intravenous placement in adults presenting to an emergency department: a randomized clinical trial. Academic Emergency Medicine, 21(8), pp. 858–863. https://dx.doi.org/10.1111/acem.12437.PMid:25176152
Bauman, M., Braude, D., & Crandall, C., 2009. Ultrasoundguidance vs. standard technique in difficult vascular access patients by ED technicians. American Journal of Emergency Medicine, 27(2), pp. 135–140. https://dx.doi.org/10.1016/j.ajem.2008.02.005. PMid:19371518
Bernatchez, S. F., 2014. Care of peripheral venous catheter sites: advantages of transparent film dressings over tape and gauze. Journal of the Association for Vascular Access, 19(4), pp. 256–261. https://dx.doi.org/10.1016/j.java.2014.09.001.
Chapman, L.L., Sullivan, B., Pacheco, A.L., Draleau, C.P. & Becker, B.M., 2011. VeinViewer-assisted intravenous catheter placement in a pediatric emergency department. Academic Emergency Medicine, 18(9), pp. 966–971. https://dx.doi.org/10.1111/j.1553-2712.2011.01155.x. PMid:21854488
Chiao, F.B., Resta-Flarer, F., Lesser, J., Ng, J., Ganz, A., Pino-Luey, D., et al., 2013. Vein visualization: patient characteristic factors and efficacy of a new infrared vein finder technology. British Journal of Anaesthesia, 110(6), pp. 966–971. https://dx.doi.org/10.1093/bja/aet003. PMid: 23384732
Chinnock, B., Thornton, S. & Hendey, G.W., 2007. Predictors of success in nurse-performed ultrasound-guided cannulation. The Journal of emergency medicine, 33(4), pp. 401–405. https://dx.doi.org/10.1016/j.jemermed.2007.02.027. PMid:17976752
Cuper, N.J., De Graaff, J.C., Verdaasdonk, R.M., Van Der Werff, D.B.M. & Kalkman, C.J., 2010. Predictability of complicated peripheral venous access in children. Pediatric Research, 68, p. 592. https://dx.doi.org/10.1203/00006450-201011001-01198.
Cuper, N.J., Klaessens, J.H.G., Jaspers, J.E.N., de Roode, R., Noordmans, H.J., de Graaff, J.C., et al., 2013. The use of nearinfrared light for safe and effective visualization of subsurface blood vessels to facilitate blood withdrawal in children. Medical Engineering and Physics, 35(4), pp. 433–440. https://dx.doi.org/10.1016/j.medengphy.2012.06.007. PMid:22841651
Dunn, M.R., & Conrad, S., 2005. Utilization of infrared transillumination as an aid for peripheral arterial access. Academic Emergency Medicine, 12(5, Suppl 1), pp. S34–S35.
Ernst, D.J., 2009. Take the guesswork out of venepunctures. MLO: Medical Laboratory Observer, 41(4), pp. 18–20. PMid:19456062
Fields, J.M., Piela, N.E., & Ku, B.S., 2014. Association between multiple IV attempts and perceived pain levels in the emergency department. The journal of vascular access, 15(6), pp. 514–518. https://dx.doi.org/10.5301/jva.5000282. PMid:25198807
Fukuroku, K., Narita, Y., Taneda, Y., Kobayashi, S. & Gayle, A.A., 2016. Does infrared visualization improve selection of venepuncture sites for indwelling needle at the forearm in secondyear nursing students? Nurse education in practice, 18, pp. 1–9. https://dx.doi.org/10.1016/j.nepr.2016.02.005. PMid:27235559
Fumagalli, S., Torricelli, G., Massi, M., Calvani, S., Boni, S., Roberts, A.T., et al., 2016. Effects of a new device to guide venous puncture in elderly critically ill patients: results of a pilot randomized study. Aging clinical and experimental research. https://dx.doi.org/10.1007/s40520-016-0547-0 PMid: 26914485
De Graaff, J.C., Cuper, N.J., Mungra, R.A.A., Vlaardingerbroek, K., Numan, S.C. & Kalkman, C.J., 2013. Near-infrared light to aid peripheral intravenous cannulation in children: a cluster randomised clinical trial of three devices. Anaesthesia, 68(8), pp. 835–845. https://dx.doi.org/10.1111/anae.12294. PMid:23763614
Gregg, S.C., Murthi, S.B., Sisley, A.C., Stein, D.M. & Scalea, T.M., 2010. Ultrasound-guided peripheral intravenous access in the intensive care unit. Journal of Critical Care, 25(3), pp. 514–519. http://dx.doi.org/10.1016/j.jcrc.2009.09.003. PMid:19836193
Guillon, P., Makhloufi, M., Baillie, S., Roucoulet, C., Dolimier, E. & Masquelier, A.M., 2015. Prospective evaluation of venous access difficulty and a near-infrared vein visualizer at four French haemophilia treatment centres. Haemophilia, 21(1), pp. 21–26. http://dx.doi.org/10.1111/hae.12513 PMid:25335191
Heinrichs, J., Fritze, Z., Vandermeer, B., Klassen, T. & Curtis, S., 2013. Ultrasonographically guided peripheral intravenous cannulation of children and adults: a systematic review and metaanalysis. Annals of emergency medicine, 61(4), pp. 444–454, e1. http://dx.doi.org/10.1016/j.annemergmed.2012.11.014. PMid:23415740
Hess, H.A., 2010. A biomedical device to improve pediatric vascular access success. Pediatric nursing, 36(5), pp. 259–263. PMid:21067078
Higgins, J.P.T. & Green, S., eds., 2011. Cochrane handbook for systematic reviews of interventions, Version 5.1.0. London: The Cochrane Collaboration. Available from http://handbook.cochrane.org [20. 9. 2016].
InSono, 2015. InSono Biomedical division EasyVein. Available from http://www.insono.it/wp-content/uploads/presentazione_EasyVein.pdf [20. 9. 2016].
John, J.M., 2007. Transillumination for vascular access: old concept, new technology. Pediatric Anesthesia, 17(2), pp. 197–198. https://dx.doi.wiley.com/10.1111/j.1460-9592.2006.02061.x. PMid:17238901
Juric, S., Flis, V., Debevc, M., Holzinger, A. & Zalik, B., 2014. Towards a low-cost mobile subcutaneous vein detection solution using near-infrared spectroscopy. Scientific World Journal, p. 365902. https://dx.doi.org/10.1155/2014/365902. PMid:24883388
Juric, S. & Zalik, B., 2014. An innovative approach to near-infrared spectroscopy using a standard mobile device and its clinical application in the real-time visualization of peripheral veins. BMC Medical Informatics and Decision Making, 14(100), p. 9. https://dx.doi.org/10.1186/s12911-014-0100-z. PMid:25421099
Kaddoum, R.N., Anghelescu, D.L., Parish, M.E., Wright, B.B., Trujillo, L., Wu, J., et al., 2012. A randomized controlled trial comparing the AccuVein AV300 device to standard insertion technique for intravenous cannulation of anesthetized children. Paediatric Anaesthesia, 22(9), pp. 884–889. https://dx.doi.org/10.1111/j.1460-9592.2012.03896.x. PMid:22694242
Keyko, K., Cummings, G.G.,Yonge, O. & Wong, C.A., 2016. Work engagement in professional nursing practice: a systematic review. International Journal of Nursing Studies, 61,pp. 142–164. https://dx.doi.org/10.1016/j.ijnurstu.2016.06.003. PMid:27351831
Kuensting, L.L., DeBoer, S., Holleran, R., Shultz, B.L., Steinmann, R.A. & Venella, J., 2009. Difficult Venous Access in Children: Taking Control. Journal of Emergency Nursing, 35(5), pp. 419–424. http://dx.doi.org/10.1016/j.jen.2009.01.014. PMid:19748021
Lamperti, M. & Pittiruti, M., 2013. II. Difficult peripheral veins: turn on the lights. British Journal of Anaesthesia, 110(6), pp. 888–891. https://dx.doi.org/10.1093/bja/aet078. PMid:23687310
Medical, E., 2015. Evena eyes-on glasses wearable medical computing & precision IV placement. Available at: http://evenamed.com/wp-content/uploads/2015/11/Evena-Eyes-On-Glasses-datasheet-1115.pdf [15. 9. 2016].
Melnyk, B. M. & Fineout-Overholt, E., 2015. Evidence-based practice in nursing & healthcare : a guide to best practice. Philadelphia: Wolters Kluwer Health.
Miyake, R.K., Zeman, H.D., Duarte, F.H., Kikuchi, R., Ramacciotti, E., Lovhoiden, G., et al., 2006. Vein imaging: a new method of near infrared imaging, where a processed image is projected onto the skin for the enhancement of vein treatment. Dermatologic surgery, 32(8), pp. 1031–1038. https://dx.doi.org/10.1111/j.1524-4725.2006.32226.x PMid:16918565
Moher, D., Liberati, A., Tetzlaff, J., Altman, D.G. & PRISMA Group, 2010. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. International Journal of Surgery, 8(5), pp. 336–341. https://dx.doi.org/10.1016/j.ijsu.2010.02.007. PMid:20171303
Pagnutti, L., Bin, A., Donato, R., Di Lena, G., Fabbro, C., Fornasiero, L., et al., 2016. Difficult intravenous access tool in patients receiving peripheral chemotherapy: a pilotvalidation study. European Journal of Oncology Nursing, 20, pp. 58–63. https://dx.doi.org/10.1016/j.ejon.2015.06.008. PMid:26163026
Perry, A.M., Caviness, A.C. & Hsu, D.C., 2011. Efficacy of a near-infrared light device in pediatric intravenous cannulation: a randomized controlled trial. Pediatric emergency care, 27(1), pp. 5–10. https://dx.doi.org/10.1097/PEC.0b013e3182037caf. PMid:21178814
Peterson, K.A., Phillips, A.L., Truemper, E. & Agrawal, S., 2012. Does the use of an assistive device by nurses impact peripheral intravenous catheter insertion success in children? Journal of Pediatric Nursing, 27(2), pp. 134–143. https://dx.doi.org/10.1016/j.pedn.2010.10.009. PMid:22341192
Popay, J., Roberts, H., Sowden, A., Petticrew, M., Arai, L., Rodgers, M., et al., 2006. Guidance on the conduct of narrative synthesis in systematic reviews. A product from the ESRC methods programme Version, 1, p. 92.
Ramer, L., Hunt, P., Ortega, E., Knowlton, J., Briggs, R. & Hirokawa, S., 2015. Effect of Intravenous (IV) Assistive Device (VeinViewer) on IV access attempts, procedural time, and patient and nurse satisfaction. Journal of pediatric oncology nursing, 33(4), pp. 273–281. https://dx.doi.org/10.1177/1043454215600425. PMid:26510643
Sebbane, M., Claret, P.-G., Lefebvre, S., Mercier, G., Rubenovitch, J., Jreige, R., et al., 2013. Predicting peripheral venous access difficulty in the emergency department using body mass index and a clinical evaluation of venous accessibility. The Journal of emergency medicine, 44(2), pp. 299–305. https://dx.doi.org/10.1016/j.jemermed.2012.07.051. PMid:22981661
Sirk, B., Fekonja, Z., & Strnad, M., 2013. Identifikacija žil in vzpostavitev periferne venske poti s pomočjo. In: R. Vajd & M. Gričar, eds. Urgentna medicina: izbrana poglavja 2013. Dvajseti mednarodni simpozij o urgentni medicini. Portorož, Slovenija, 13.-15. junij 2013. Ljubljana: Slovensko združenje za urgentno medicino, pp. 388–389.
Strehle, E. M., 2010. Making the invisible visible: near-infrared spectroscopy and phlebotomy in children. Telemedicine and e-Health, 16(8), pp. 889–893. https://dx.doi.org/10.1089/tmj.2010.0061. PMid:20925568
Strgar, M. & Macura Višić, N., 2013. Dejavniki, ki vplivajo na uvajanje periferne intravenozne kanile – primerjava med internistično in pediatrično prvo pomočjo v Splošni bolnišnici Jesenice. In: D. Klemenc, et al., eds. Moč za spremembe – medicinske sestre in babice smo v prvih vrstah zdravstvenega sistema: zbornik prispevkov z recenzijo / 9. kongres zdravstvene in babiške nege Slovenije, Brdo pri Kranju, 9. in 10. maj 2013. Ljubljana: Zbornica zdravstvene in babiške nege Slovenije – Zveza strokovnih društev medicinskih sester, babic in zdravstvenih tehnikov Slovenije, pp. 389–395.
Sun, C.Y., Lee, K.C., Lin, I.H., Wu, C.L., Huang, H.P., Lin, Y.Y., et al., 2013. Near-infrared light device can improve intravenous cannulation in critically ill children. Pediatrics and Neonatology, 54(3), pp. 194–197. https://dx.doi.org/10.1016/j.pedneo.2012.12.012. PMid:23597539
Szmuk, P., Steiner, J., Pop, R.B., Farrow-Gillespie, A., Mascha, E.J. & Sessler, D.I., 2013. The VeinViewer vascular imaging system worsens first-attempt cannulation rate for experienced nurses in infants and children with anticipated difficult intravenous access. Anesthesia and analgesia, 116(5), pp. 1087–1092. https://dx.doi.org/10.1213/ANE.0b013e31828a739e. PMid:23492965
Walsh, G., 2008. Difficult peripheral venous access: recognizing and managing the patient at risk. Journal of the Association for Vascular Access, 13(4), pp. 198–203. https://dx.doi.org/10.2309/java.13-4-7
Young, J.M. & Solomon, M.J., 2009. How to critically appraise an article. Nature Clinical Practice Gastroenterology & Hepatology, 6(2), pp. 82–91. https://dx.doi.org/10.1038/ncpgasthep1331. PMid:19153565
Downloads
Published
How to Cite
Issue
Section
License
As the author undersigned hereby, I transfer, assign, or otherwise convey the following authorship rights as comprised in the Copyright and Related Rights Act (CRRA) to the Slovenian Nursing Review, Ob železnici 30A, 1000 Ljubljana: the right of reproduction - the exclusive right to fix the work in a material medium or in another copy directly or indirectly, temporarily or permanently, by any means and in any digital form, in whole or in part (CRRA, Article 23); the right of distribution (CRRA, Article 24); the right of making a work available and accessible through the internet (CRRA, Article 32a); the right of transformation, especially the exclusive right to translate a pre-existing work (CRRA, Article 33). The transfer of author rights applies to the article in its entirety, including pictorial and/or graphic works and possible supplements. The transfer of rights is exclusive and unlimited in duration or territory.